Chapter 11

Error code list

 

 

 

 

 

 

Code

Error

 

 

Measures

 

 

 

 

E-C3

Embroidering data buffer empty

Is the IF cable disconnected? If it is connected normally, the cable or the

main board is faulty.

 

 

 

 

 

 

 

 

 

E-C4

Presser foot down error

Press the STOP or turn on the F/B switch on the head to either side. If the

same error occurs again, adjust the presser foot switch.

 

 

 

 

 

 

 

 

 

 

E-C5

Measured voltage value could not be received form

 

 

 

 

the lower shaft motor CPU.

 

 

 

 

 

This is not usually displayed.

 

 

 

 

 

 

E-C6

Voltage value could not be transferred to the lower

 

 

 

 

 

 

shaft motor CPU.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The machine may be being tested in the BC test mode. Exit the test mode

E-C7

Lower shaft error

or turn the power off and on once. If the same error occurs again, the main

 

 

PCB is faulty.

 

 

 

 

 

E-C8

Hook motor origin point error

Check the operation of the main shaft brake and the stop position of the

main shaft (100 degrees).

 

 

 

 

 

 

 

 

 

 

 

 

The

is pressed while no sewing data has been transferred to the em-

E-C9

Embroidering start error

broidery machine. Clear this error by the STOP . To start sewing, transfer

 

 

necessary data from the machine controller and press the

.

 

 

 

 

 

E-CA

No sewing permission is given from PC.

This is not usually displayed.

 

 

 

 

 

 

 

Press the STOP or turn on the F/B switch on the head to either side to cancel

E-CB

Spindle rotation speed error

the error and press the

. If the same error occurs again, there is a

 

 

possibility that the spindle is overloaded.

 

 

 

 

 

 

E-CC

Shuttle thread entanglement automatic reset

This is not usually displayed.

 

 

 

 

 

E-CD

Speed command can not be received.

Turn the power off and on once. If the same error occurs again, the main

PCB is faulty.

 

 

 

 

 

 

 

 

 

E-CE

Cylinder bed position error

Secure the bed. If the bed is secured, the bed sensor position may be

faulty. Readjust it.

 

 

 

 

 

 

 

 

 

E-CF

Rated voltage value could not be received from the

Turn the power off and on once. If the same error occurs again, the main

lower shaft motor CPU.

PCB is faulty.

 

 

 

 

 

 

 

 

E-D0

Power PC board error

Turn the power off and on once. If the same error occurs again, the power

PCB is faulty.

 

 

 

 

 

 

 

 

 

E-D1

Cooling fan motor stop B Tum the power off.

Turn off the power and check the fan harness. Turn on the power again. If

the same error occurs again, the fan or the power PCB is faulty.

 

 

 

 

 

 

E-D2

Power voltage upper limit error

(1) The voltage setting is improper. -> Set it again.

 

(2) Press the STOP or turn on the F/B switch on the head to either side. If

 

 

E-D3

Power voltage lower limit error

the same error occurs again, the power PCB or the power supply is

faulty.

 

 

 

 

 

 

 

 

 

 

 

 

E-E1

X-axis pulse motor overcurrent stop

 

 

 

 

 

 

Turn the power off and on once.

 

E-E2

Y-axis pulse motor overcurrent stop

 

 

 

 

 

 

 

 

E-E3

Cooling fan motor stop A Press R.

Turn off the power and check the fan harness. Turn on the power again. If

the same error occurs again, the fan or the power PCB is faulty.

 

 

 

 

 

E-E4

Lower shaft communication error

Turn the power off and on once. If the same error occurs again, the main

PCB is faulty.

 

 

 

 

 

 

 

 

 

 

 

 

E-E5

Over-run error during interfacing to main PCB CPU

 

 

 

 

 

 

 

 

 

 

E-E6

Framing error during interfacing to main PCB CPU

 

 

 

 

 

 

This is not usually displayed.

 

 

E-E7

Parity error during interfacing to main PCB CPU

 

 

 

 

 

 

 

 

 

 

 

 

E-E8

Receiving time up error during interfacing to main

 

 

 

 

PCB CPU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BES-962BCBES-1262BC

249

Page 251
Image 251
Brother BES-962BC instruction manual 249