| Chapter 11 | Error code list | |
|
|
|
|
|
| |
Code | Error |
|
| Measures |
| |
|
|
| ||||
Embroidering data buffer empty | Is the IF cable disconnected? If it is connected normally, the cable or the | |||||
main board is faulty. |
|
| ||||
|
|
|
| |||
|
|
| ||||
Presser foot down error | Press the STOP or turn on the F/B switch on the head to either side. If the | |||||
same error occurs again, adjust the presser foot switch. |
| |||||
|
|
| ||||
|
|
|
|
|
| |
Measured voltage value could not be received form |
|
|
|
| ||
the lower shaft motor CPU. |
|
|
|
| ||
| This is not usually displayed. |
|
| |||
|
|
|
| |||
Voltage value could not be transferred to the lower |
|
| ||||
|
|
|
| |||
shaft motor CPU. |
|
|
|
| ||
|
|
|
|
| ||
|
|
| ||||
|
| The machine may be being tested in the BC test mode. Exit the test mode | ||||
Lower shaft error | or turn the power off and on once. If the same error occurs again, the main | |||||
|
| PCB is faulty. |
|
| ||
|
|
| ||||
Hook motor origin point error | Check the operation of the main shaft brake and the stop position of the | |||||
main shaft (100 degrees). |
|
| ||||
|
|
|
| |||
|
|
|
| |||
|
| The | is pressed while no sewing data has been transferred to the em- | |||
Embroidering start error | broidery machine. Clear this error by the STOP . To start sewing, transfer | |||||
|
| necessary data from the machine controller and press the | . | |||
|
|
|
|
| ||
No sewing permission is given from PC. | This is not usually displayed. |
|
| |||
|
|
| ||||
|
| Press the STOP or turn on the F/B switch on the head to either side to cancel | ||||
Spindle rotation speed error | the error and press the | . If the same error occurs again, there is a | ||||
|
| possibility that the spindle is overloaded. |
| |||
|
|
|
|
| ||
Shuttle thread entanglement automatic reset | This is not usually displayed. |
|
| |||
|
|
| ||||
Speed command can not be received. | Turn the power off and on once. If the same error occurs again, the main | |||||
PCB is faulty. |
|
| ||||
|
|
|
| |||
|
|
| ||||
Cylinder bed position error | Secure the bed. If the bed is secured, the bed sensor position may be | |||||
faulty. Readjust it. |
|
| ||||
|
|
|
| |||
|
|
| ||||
Rated voltage value could not be received from the | Turn the power off and on once. If the same error occurs again, the main | |||||
lower shaft motor CPU. | PCB is faulty. |
|
| |||
|
|
| ||||
|
|
| ||||
Power PC board error | Turn the power off and on once. If the same error occurs again, the power | |||||
PCB is faulty. |
|
| ||||
|
|
|
| |||
|
|
| ||||
Cooling fan motor stop B Tum the power off. | Turn off the power and check the fan harness. Turn on the power again. If | |||||
the same error occurs again, the fan or the power PCB is faulty. | ||||||
|
| |||||
|
|
|
| |||
Power voltage upper limit error | (1) The voltage setting is improper. |
| ||||
(2) Press the STOP or turn on the F/B switch on the head to either side. If | ||||||
|
| |||||
Power voltage lower limit error | the same error occurs again, the power PCB or the power supply is | |||||
faulty. |
|
| ||||
|
|
|
| |||
|
|
|
|
|
| |
|
|
|
| |||
|
| Turn the power off and on once. |
| |||
| ||||||
|
|
|
| |||
|
|
| ||||
Cooling fan motor stop A Press R. | Turn off the power and check the fan harness. Turn on the power again. If | |||||
the same error occurs again, the fan or the power PCB is faulty. | ||||||
|
| |||||
|
|
| ||||
Lower shaft communication error | Turn the power off and on once. If the same error occurs again, the main | |||||
PCB is faulty. |
|
| ||||
|
|
|
| |||
|
|
|
|
|
| |
|
|
|
| |||
|
|
|
|
|
| |
Framing error during interfacing to main PCB CPU |
|
|
|
| ||
|
| This is not usually displayed. |
|
| ||
Parity error during interfacing to main PCB CPU |
|
| ||||
|
|
|
| |||
|
|
|
|
|
| |
Receiving time up error during interfacing to main |
|
|
|
| ||
PCB CPU |
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
|
|
249 |