Chapter 12 Troubleshooting

Symptom

Measures

 

 

Thread is frequently tangled in the

• Is thread tangled in the rotary hook?

rotary hook.

Clean the rotary hook.

Conduct BC sensor test of the test mode.

If there is any failure, replace the lower shaft module with a new one.

Conduct automatic out-of-step limit measurement of BC automatic test in the test mode.

Replace the lower shaft module with a new one if there is any fault.

Check to see if the lower shaft fan of the head with which the error frequently occurs is correctly rotating.

If the fan is at standstill, check to see if connection from the lower shaft fan to the BC PCB is proper. Replace the lower shaft fan with a new one.

If all the lower shaft fans are at standstill, check fuse F4 on the power supply PCB in the control box.

Is the hole next to the bed with which the error frequently occurs clogged with dust?

If so, clean it.

The lower shaft motor zero point er-

• Is thread tangled in the rotary hook?

ror occurs.

Clean the rotary hook.

Is the lower shaft with which the error occurs rotating?

If so, check to see if connection from the lower shaft sensor PCB to the BC PCB is proper. Adjust the lower shaft sensor. Replace the lower shaft sensor PCB with a new one.

If the lower shaft with which the error occurs is not rotating, check to see if connection from the lower shaft motor to the BC PCB is proper. Replace the lower shaft module with a new one. Replace the BC PCB with a new one.

The lower shaft motor standby posi-

• Is the rotary hook rotated manually?

tion error occurs.

This is not a fault.

Check to see if connection from the lower shaft sensor PCB to the BC PCB is proper. Replace the lower shaft module with a new one.

The lower shaft overheat error oc- •

Check to see if the lower shaft fan is normally rotating. If the fan is at

curs.

standstill, check to see if connection from the lower shaft fan to the BC

 

PCB is proper. Replace the lower shaft fan with a new one.

If all the lower shaft fans are at standstill, check fuse F4 on the power

 

supply PCB in the control box.

• Is the hole next to the bed with which the error frequently occurs clogged

 

with dust?

 

If so, clean it.

• Check to see if connection from the thermister of the lower shaft module

 

to the BC PCB is proper.

BES-962BCBES-1262BC

257

Page 259
Image 259