Chapter 2 Preparation of Embroidery Machine
•By changing the tubular round arm mounting width, various sizes can be set.
Note) Change the width, referring to the pin position.
360mm | 400mm |
|
600mm
500mm
Note) If two pins cannot be inserted, remove one.
•If a tubular round arm has a backlash:
Follow these steps for adjustment:
Screw q
Tubular round arm support
1.Move the end of the tubular round arm to the left.
2.If a clearance is left as shown in the figure, loosen screw q and adjust the tubular round arm support so as to eliminate the clearance between the support and the X- feed frame. Tighten screw q.
*Follow the same steps when moving the end face of a tubular round arm to the right.
49 |