Appendix C Troubleshooting

Troubleshooting the CSS 11501

Troubleshooting the CSS 11501

CSS 11501 status is indicated by the Status LED on the front panel. For information about the CSS 11501 LEDs, refer to Chapter 2, Cabling the CSS.

Table C-4provides suggestions for correcting problems that may occur with the CSS 11501.

Table C-4 Troubleshooting the CSS 11501

Symptom

Recommended Action

 

 

At boot up, the following

When there is a failure on a CSS 11501

message appears:

component, the CSS 11501 attempts the boot

CHMGR: Slot slot/subslot

process three times. If the boot is unsuccessful,

the CSS generates a log message and saves it in

had diagnostic failures -

NOT STARTING UP

the boot.log file. Obtain technical assistance.

 

Refer to the “About This Guide”. For

 

information on log files, see “Log File

 

Information”.

 

 

During normal CSS operation,

Check the six fans in the chassis. The

the following message appears:

CSS 11501 is running at a temperature that is

Temperature has reached x

too high, as indicated by the x variable. When a

fan failure occurs, obtain technical assistance.

celsius for slot number

 

 

 

 

Cisco 11500 Series Content Services Switch Hardware Installation Guide

 

 

 

 

 

 

78-13884-03

 

 

C-19

 

 

 

Page 149
Image 149
Cisco Systems 11500 Series manual Troubleshooting the CSS, Symptom Recommended Action