Chapter 2 Cabling the CSS
Connecting the Chassis to Ground
Attaching the Grounding Cable
The following procedure describes how to attach:
•The grounding lug to the grounding cable
•The grounding cable to the chassis
Warning When you install or replace the unit, the ground connection must always be made first and disconnected last.
1.Power off the chassis by setting the power switch (or switches) to the O (off) position.
2.Strip the covering from the end of the grounding wire (Figure
Lug | Strip Length |
|
|
Panduit no. | 13/16 inch (2 cm) |
(supplied in accessory kit) |
|
|
|
Panduit no. | 1 1/16 inch (2.7 cm) |
(long barrel) |
|
|
|
Thomas & Betts no. | 3/4 inch (1.9 cm) |
| |
|
|
Burndy no. YA6CL2TC10 | 7/8 inch (2.2 cm) |
|
|
3.Insert the stripped end of the grounding wire into the open end of a lug
(Figure 2-10) and crimp the grounding lug securely to the wire. Use the lug manufacturer’s recommended crimping tool and crimping procedure to ensure a proper crimp.
| Cisco 11500 Series Content Services Switch Hardware Installation Guide |