Chapter13 Configuring IEEE 802.1Q and L ayer 2 Protocol Tunneling Configuring Layer 2 Protocol Tunneling
Use the no l2protocol-tunnel [point-to-point [pagp | lacp | udld]] interface configuration command to
disable point-to-point protocol tunneling for one of the Layer 2 protocols or for all three. Use the no
l2protocol-tunnel shutdown-threshold [point-to-point [pagp | lacp | udld]] and the no
l2protocol-tunnel drop-threshold [[point-to-point [pagp | lacp | udld]] commands to return the
shutdown and drop thresholds to the default settings.
Configuring the Customer Switch
After configuring the SP edge switch, begin in privileged EXEC mode and follow these steps to
configure a customer switch for Layer 2 protocol tunneling for EtherChannels:
Step7 l2protocol-tunnel drop-threshold
[point-to-point [pagp | lacp | udld]]
value
(Optional) Configure the threshold for packets-per-second accepted for
encapsulation. The interface drops packets if the configured threshold is
exceeded. If no protocol option is specified, the threshold applies to each of
the tunneled Layer 2 protocol types. The range is 1 to 4096. The de fault i s
to have no threshold configured.
Note If you also set a shutdown threshold on this interface, the
drop-threshold value must be less than or equal to the
shutdown-threshold value.
Step8 no cdp enable If the interface is an NNI, disable CDP on the interface. UNIs do not support
CDP.
Step9 spanning-tree bpdufilter enable If the interface is an NNI, enable BPDU filtering on the interface. UNIs do
not support STP PBDU filtering.
Step10 exit Return to global configuration mode.
Step11 errdisable recovery cause l2ptguard (Optional) Configure the recovery mechanism from a Layer 2
maximum-rate error so that the interface is re-enabled and can try again.
Errdisable recovery is disabled by default; when enabled, the default time
interval is 300 seconds.
Step12 l2protocol-tunnel cos value (Optional) Configure the CoS value for all tunneled Layer 2 PDUs. The
range is 0 to 7; the default is the default CoS value for the interface. If none
is configured, the default is 5.
Step13 end Return to privileged EXEC mode.
Step14 show l2protocol Display the Layer 2 tunnel ports on the switch, including the prot ocol s
configured, the thresholds, and the counters.
Step15 copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Command Purpose
Step1 configure terminal Enter global configuration mode.
Step2 interface interface-id Enter the interface configuration mode. This should b e the c ustomer switch
port.
Step3 no shutdown Enable the port, if necessary. By default, UNIs are disabled and NNIs are
enabled.
Step4 switchport mode trunk Enable trunking on the interface.
Step5 udld enable Enable UDLD in normal mode on the interface.