TEST THE SUREVEND™ SYSTEM
1. Press , then press until the display shows one of the following:
This means the SureVend™ system is operating properly.
XX represents the location of a blockage. The sensing zone numbers 1 - 9
may appear (1 being closest to the glass). This display changes as the
location of the blockage changes, accompanied by a beep. You may use
this screen to test the product coverage of the SureVend™ sensors, but the
accuracy may be somewhat lower than in actual vend situations.
This means that calibration values are high. Press to view the
calibration values. This condition may be caused by dirt, misalignment of
the SsureVend™ sensors, or a partial blockage of a sensor.
2. From any of the previous displays, press to view the real-time calibration values.
Press to return to the screen.
A calibration value of 0 indicates a shorted detector. This will normally require replacing
the hinge-side PC assembly.
A calibration value of 1 means that the zone could no t be calibra ted, indi cating a blocke d
or damaged sensor.
Calibration values above A are abnormal and may require adjusting the alignment or
cleaning the sensors.
This indicates a loss of communication with the SureVend™ system.
Check all harness connections between the main controller and the
SureVend™ controller.
3. CONTINUE.