Programming Procedures Refreshment Center Operators’ Gu ide
4800006 70 December 2004
VIEW MACHINE TEMPERATURE
1. Press . The display shows 0 . This example shows that the machine
temperature is 380 degrees Fahrenheit.
NOTE
The temperature reading may display one of the following instead of “TEMP”,
depending on conditions in the machine:
- XX is the number of minutes left in the health control grace period
(see "Health Control" on page 42)
- a health control error has occurred.
- the machine is currently in a passive defrost cycle
- the temperature has been over the health control limit for x.x minutes.
2. If “” replaces “F” or “C” after the temperature, then the temperature is invalid. The last
valid temperature is shown. Check diagnostics for the cause, usually a faulty sensor.
3. A decimal point following “F” or “C” indicates the software has turned the compressor
on. If the compressor is not on, check the related wiring.
4. A comma after the “F” or “C” indicates the software is currently performing a defrost.
5. To change the display units, press . The display now shows .
6. CONTINUE.
VIEW SUREVEND SOFTWARE VERSION
1. Press , and press until the display shows .”XXX” represents
the current SureVend software version number.
2. CONTINUE.
VIEW SOFTWARE VERSION
1. Press , and press until the display shows . "XXX.XX" represents
the current software version number.
2. CONTINUE.