Figure 11- 12. Tx Error Analysis window (table)

The following fields may be set or viewed:

ParameterDescription

Time Interval [1s ]

Record Number [200]

ExDefer

CRC Error

LateColl

ExColl

SingColl

Coll

Show/Hide

Clear

View Table

View Line Chart

Select the desired setting between 1s and 60s, where "s" stands for seconds. The default value is one second.

Select number of times the Switch will be polled between 20 and 200. The default value is 200.

Counts the number of packets for which the first transmission attempt on a particular interface was delayed because the medium was busy.

Counts otherwise valid packets that did not end on a byte (octet) boundary.

Counts the number of times that a collision is detected later than 512 bit-times into the transmission of a packet.

Excessive Collisions. The number of packets for which transmission failed due to excessive collisions.

Single Collision Frames. The number of successfully transmitted packets for which transmission is inhibited by more than one collision.

An estimate of the total number of collisions on this network segment.

Check whether or not to display ExDefer, LateColl, ExColl, SingColl, and Coll errors.

Clicking this button clears all statistics counters on this window.

Clicking this button instructs the Switch to display a table rather than a line graph.

Clicking this button instructs the Switch to display a line graph rather than a table.