Table 1-4. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1414

CPU # Thermtrip

Specified microprocessor is out of

See "Troubleshooting System

 

 

acceptable temperature range and

Cooling Problems" on page 109.

 

 

has halted operation.

If the problem persists, ensure

 

 

 

that the microprocessor heat

 

 

 

sinks are properly installed. See

 

 

 

"Troubleshooting the

 

 

 

Microprocessors" on page 118.

 

 

 

NOTE: The LCD continues to

 

 

 

display this message until the

 

 

 

system’s power cord is

 

 

 

disconnected and reconnected to

 

 

 

the AC power source, or the SEL is

 

 

 

cleared using either Server

 

 

 

Assistant or the BMC Management

 

 

 

Utility. See the Dell OpenManage

 

 

 

Baseboard Management

 

 

 

Controller User’s Guide for

 

 

 

information about these utilities.

 

 

 

 

E1418

CPU # Presence

Specified processor is missing or

See "Troubleshooting the

 

 

bad, and the system is in an

Microprocessors" on page 118.

 

 

unsupported configuration.

 

E141C

CPU Mismatch

Processors are in a configuration

 

 

unsupported by Dell.

Ensure that your processors match and conform to the type described in the Microprocessor Technical Specifications outlined in your system’s Getting Started Guide.

E141F

CPU Protocol

The system BIOS has reported a

See "Getting Help" on page 131.

 

 

processor protocol error.

 

 

 

 

 

E1420

CPU Bus PERR

The system BIOS has reported a

See "Getting Help" on page 131.

 

 

processor bus parity error.

 

 

 

 

 

E1421

CPU Init

The system BIOS has reported a

See "Getting Help" on page 131.

 

 

processor initialization error.

 

 

 

 

 

E1422

CPU Machine Chk

The system BIOS has reported a

See "Getting Help" on page 131.

 

 

machine check error.

 

 

 

 

 

E1618

PS # Predictive

Power supply voltage is out of

See "Troubleshooting the Power

 

 

acceptable range; specified power

Supply" on page 108.

 

 

supply is improperly installed or

 

 

 

faulty.

 

18

About Your System

Page 18
Image 18
Dell 1900 E1414 CPU # Thermtrip, E1418 CPU # Presence, E141C CPU Mismatch, E141F CPU Protocol, E1420 CPU Bus Perr