Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E201F | DRAC Config | Dell remote access controller | Check screen for specific error |
|
| (DRAC) configuration failure. | messages. |
|
|
| Ensure that DRAC cables and |
|
|
| connectors are properly seated. If |
|
|
| problem persists, see your DRAC |
|
|
| documentation. |
|
|
|
|
E2020 | CPU Config | CPU configuration failure. | Check screen for specific error |
|
|
| messages. |
|
|
|
|
E2021 | Memory | Incorrect memory configuration. | Check screen for specific error |
| Population | Memory population order | messages. See "Troubleshooting |
|
| incorrect. | System Memory" on page 110. |
|
|
|
|
E2022 | POST Fail | General failure after video. | Check screen for specific error |
|
|
| messages. |
|
|
|
|
E2110 | MBE DIMM ## & ## | One of the DIMMs in the set | See "Troubleshooting System |
|
| implicated by "## & ##" has | Memory" on page 110. |
|
| had a memory |
|
|
| (MBE). |
|
|
|
|
|
E2111 | SBE Log Disable | The system BIOS has disabled | See "Troubleshooting System |
| DIMM ## | memory | Memory" on page 110. |
|
| logging, and will not resume |
|
|
| logging further SBEs until the |
|
|
| system is rebooted. "##" |
|
|
| represents the DIMM implicated |
|
|
| by the BIOS. |
|
|
|
|
|
E2112 | Mem Spare DIMM | The system BIOS has spared the | See "Troubleshooting System |
| ## | memory because it has | Memory" on page 110. |
|
| determined that the memory had |
|
|
| too many errors. "## & ##" |
|
|
| represents the DIMM pair |
|
|
| implicated by the BIOS. |
|
|
|
|
|
E2113 | Mem Mirror DIMM | They system BIOS has disabled | See "Troubleshooting System |
| ## & ## | memory mirroring because it has | Memory" on page 110. |
|
| determined that one half of the |
|
mirror has had too many errors. "## & ##" represents the DIMM pair implicated by the BIOS.
About Your System
21