Dell 1900 Diskette drive n seek, Failure, Diskette read failure, Diskette subsystem reset

Models: 1900

1 166
Download 166 pages 61.1 Kb
Page 25
Image 25

Table 1-5. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Diskette drive n seek

Incorrect configuration settings in the

Run the System Setup program to

failure

System Setup program.

correct the settings. See "Using the

 

 

System Setup Program" on page 33.

 

Faulty or improperly installed diskette

Replace the diskette. If the problem

 

drive.

persists, see "Troubleshooting a Diskette

 

 

Drive" on page 112.

 

Loose diskette drive interface cable, or

Reseat diskette drive interface cable, or

 

loose power cable.

power cable. See "Troubleshooting a

 

 

Diskette Drive" on page 112.

 

 

 

Diskette read failure

Faulty or improperly inserted diskette.

Replace the diskette. If the problem

 

 

persists, see "Troubleshooting a Diskette

 

 

Drive" on page 112.

 

 

 

Diskette subsystem reset

Faulty or improperly installed

Replace the diskette. If the problem

failed

diskette.

persists, see "Troubleshooting a Diskette

 

 

Drive" on page 112.

Drive not ready

Diskette missing from or improperly

 

inserted in diskette drive.

Replace the diskette. If the problem persists, see "Troubleshooting a Diskette Drive" on page 112.

Error: Incorrect memory configuration. DIMMs must be installed in pairs of matched memory size, speed, and technology.

Mismatched or unmatched DIMMs installed; faulty or improperly seated memory module(s).

Ensure that all pairs of memory modules are of the same type and size and that they are properly installed. See "Memory" on page 80. If the problem persists, see "Troubleshooting System Memory" on page 110.

Error: Memory failure detected. Memory size reduced. Replace the faulty DIMM as soon as possible.

Faulty or improperly seated memory

See "Troubleshooting System Memory"

module(s).

on page 110.

!!*** Error: Remote Access

Remote Access Controller

Controller initialization

initialization failure

failure*** RAC virtual USB

 

devices may not be

 

available...

 

Ensure that the Remote Access Controller is properly installed. See "Installing a RAC Card" on page 85.

FBD training error: The following branch has been disabled: Branch x

The specified branch (channel pair) contains DIMMs that are incompatible with each other.

Ensure that only Dell-qualified memory is used. Dell recommends purchasing memory upgrade kits directly from www.dell.com or your Dell sales agent to ensure compatibility.

About Your System

25

Page 25
Image 25
Dell 1900 owner manual Diskette drive n seek, Failure, Diskette read failure, Diskette subsystem reset, Drive not ready