Dell 1900 E1913 CPU & Firmware, Mismatch, E2010 No Memory, E2011 Mem Config Err, E2014 Cmos Fail

Models: 1900

1 166
Download 166 pages 61.1 Kb
Page 20
Image 20

Table 1-4. LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

 

 

 

 

E1913

CPU & Firmware

The BMC firmware does not

Update to the latest BMC

 

Mismatch

support the CPU.

firmware. See the BMC User’s

 

 

 

Guide for more information on

 

 

 

setup and use of BMC.

 

 

 

 

E2010

No Memory

No memory is installed in the

Install memory. See "Memory" on

 

 

system.

page 80.

 

 

 

 

E2011

Mem Config Err

Memory detected, but is not

See "Troubleshooting System

 

 

configurable. Error detected

Memory" on page 110.

 

 

during memory configuration.

 

 

 

 

 

E2012

Unusable Memory

Memory is configured, but not

See "Troubleshooting System

 

 

usable. Memory subsystem

Memory" on page 110.

 

 

failure.

 

 

 

 

 

E2013

Shadow BIOS Fail

The system BIOS failed to copy

See "Troubleshooting System

 

 

its flash image into memory.

Memory" on page 110.

 

 

 

 

E2014

CMOS Fail

CMOS failure. CMOS RAM not

See "Getting Help" on page 131.

 

 

functioning properly.

 

 

 

 

 

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 131.

 

 

 

 

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 131.

 

 

 

 

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 131.

 

 

 

 

E2018

Prog Timer

Programmable interval timer

See "Getting Help" on page 131.

 

 

error.

 

 

 

 

 

E2019

Parity Error

Parity error.

See "Getting Help" on page 131.

 

 

 

 

E201A

SIO Err

SIO failure.

See "Getting Help" on page 131.

 

 

 

 

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 131.

 

 

 

 

E201C

SMI Init

System management interrupt

See "Getting Help" on page 131.

 

 

(SMI) initialization failure.

 

 

 

 

 

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 131.

 

 

 

 

E201E

POST Mem Test

BIOS POST memory test failure.

See "Troubleshooting System

 

 

 

Memory" on page 110. If problem

 

 

 

persists, see "Getting Help" on

 

 

 

page 131.