Code

Text

Causes

Corrective Actions

 

 

 

 

E1114

Ambient Temp

Ambient temperature has

See "Troubleshooting

 

exceeds

a reached a point outside

System Cooling

 

allowed range.

of the allowed range.

Problems" on page 163.

E1116 Memory

Memory has exceeded

disabled,

allowable temperature and

temp above

has been disabled to

range.

prevent damage to the

Power

components.

cycle AC.

 

Remove AC power to the system for 10 seconds and restart the system.

See "Troubleshooting System Cooling Problems" on page 163. If the problem persists, see "Getting Help" on page 187.

E1210

Motherboard

CMOS battery is missing

See "Troubleshooting the

 

battery

or the voltage is outside of

System Battery" on

 

failure.

the allowable range.

page 162.

 

Check

 

 

 

battery.

 

 

E1211

RAID

RAID battery is either

Reseat the RAID battery

 

Controller

missing, bad, or unable

connector. See "Installing

 

battery

to recharge due

the RAID Battery" on

 

failure.

to thermal issues.

page 137, and

 

Check

 

"Troubleshooting System

 

battery.

 

Cooling Problems" on

 

 

 

page 163.

 

 

 

 

E1216

3.3V Regulator

3.3 V voltage regulator

Remove and reseat the

 

failure.

has failed.

PCIe expansion cards.

 

Reseat PCIe

 

If the problem persists,

 

cards.

 

see "Troubleshooting

 

 

 

Expansion Cards" on

 

 

 

page 172.

 

 

 

 

E1229

CPU # VCORE

Specified processor

Reseat the processor(s).

 

Regulator

VCORE voltage

See "Troubleshooting

 

failure.

regulator has failed.

Processors" on page 174.

 

Reseat CPU.

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

28

About Your System

Page 28
Image 28
Dell R515 owner manual Ambient temperature has See Troubleshooting