Message

Causes

Corrective Actions

 

 

 

Thermal sensor

A memory module without a

Replace the memory

not detected

thermal sensor is installed in

module. See "System

on x

the specified memory slot.

Memory" on page 104.

Time-of-day

Faulty battery or faulty chip.

See "Troubleshooting the

clock stopped

 

System Battery" on page 162.

Time-of-day not

Incorrect Time or Date

Check the Time and Date

set - please run

settings; faulty system

settings. See "Using the

SETUP program

battery.

System Setup Program and

 

 

UEFI Boot Manager" on

 

 

page 57. If the problem

 

 

persists, replace the system

 

 

battery. See "System Battery"

 

 

on page 133.

 

 

 

Timer chip

Faulty system board.

See "Getting Help" on

counter 2 failed

 

page 187.

TPM

A TPM configuration

Information only.

configuration

command has been entered.

 

operation

The system reboots and

 

honored. System

executes the command.

 

will now reset.

 

 

TPM

This message displays during

Enter I or M to proceed.

configuration

system restart after a TPM

 

operation is

configuration command has

 

pending. Press

been entered. User

 

(I)to Ignore interaction is required to

OR (M) to Modify proceed. to allow this

change and reset the system.

WARNING: Modifying could prevent security.

TPM failure

A Trusted Platform Module

See "Getting Help" on

 

(TPM) function has failed.

page 187.