Code

Text

Causes

Corrective Actions

E1410 System Fatal

Specified processor has an

Error

internal error. The error

detected.

may or may not have

 

been caused by

 

the processor.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 187.

E1414

CPU # temp

Specified processor is out

Ensure that the processor

 

exceeding

of acceptable

heat sinks are properly

 

range.

temperature range.

installed. See

 

Check CPU

 

"Troubleshooting

 

heatsink.

 

Processors" on page 174

 

 

 

and "Troubleshooting

 

 

 

System Cooling

 

 

 

Problems" on page 163.

 

 

 

 

E1418

CPU # not

Specified processor is

Ensure that the specified

 

detected.

missing or bad,

processor is properly

 

Check CPU

and the system is in an

installed. See

 

is seated

unsupported

"Troubleshooting

 

properly.

configuration.

Processors" on page 174.

E141C

Unsupported

Processors are in an

Ensure that your

 

CPU config.

unsupported

processors match and

 

Check CPU or

configuration.

conform to the type

 

BIOS revision.

 

described in the processor

 

 

 

technical specifications

 

 

 

outlined in your system’s

 

 

 

Getting Started Guide.

 

 

 

 

E141F

CPU # protocol

The system BIOS

Remove AC power to the

 

error. Power

has reported a processor

system for 10 seconds and

 

cycle AC.

protocol error.

restart the system.

If the problem persists, see "Getting Help" on page 187.