Message

Causes

Corrective Actions

Memory set to

The memory frequency may

minimum

be intentionally set lower for

frequency.

power conservation.

 

The current memory

 

configuration may support

 

only the minimum frequency.

If not an intentional setting, check any other system messages for possible causes.

Ensure that your memory configuration supports the higher frequency.

See "General Memory Module

Installation Guidelines" on page 105.

Memory tests

POST memory test was

Information only.

terminated by

terminated by pressing the

 

keystroke.

spacebar.

 

MEMTEST lane

Invalid memory

Ensure that the memory

failure

configuration. Mismatched

modules are installed in a

detected on x

memory modules are

valid configuration.

installed.

See "General Memory

 

 

 

Module

 

 

Installation Guidelines" on

 

 

page 105.

No boot device

Faulty or missing optical

available.

drive subsystem, hard drive,

 

or hard drive subsystem, or

 

no bootable USB key

 

installed.

Use a bootable USB key, optical drive, or hard drive. If the problem persists, see "Troubleshooting an Optical Drive" on page 168, "Troubleshooting a USB Device" on page 158, "Troubleshooting an Internal USB Key" on page 167, and "Troubleshooting a Hard Drive" on page 169.

See "Using the System Setup Program and

UEFI Boot Manager" on page 57 for information on setting the order of boot devices.

46

About Your System

Page 46
Image 46
Dell R515 owner manual Memtest lane