Code

Text

Causes

Corrective Actions

 

 

 

 

E2018

Programmable

Programmable interval

Remove AC power to the

 

Timer error.

timer error.

system for 10 seconds and

 

Power cycle

 

restart the system.

 

AC.

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E2019

Parity error.

Parity error.

Remove AC power to the

 

Power cycle

 

system for 10 seconds and

 

AC.

 

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E201A

SuperIO

SIO failure.

Remove AC power to the

 

failure.

 

system for 10 seconds and

 

Power cycle

 

restart the system.

 

AC.

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E201B

Keyboard

Keyboard

Remove AC power to the

 

Controller

controller failure.

system for 10 seconds and

 

error.

 

restart the system.If the

 

Power cycle

 

problem persists,

 

AC.

 

see "Getting Help" on

 

 

 

page 187.

E201C SMI

System management

initialization

interrupt (SMI)

failure.

initialization failure.

Power cycle

 

AC.

 

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 187.

E201D Shutdown test

BIOS shutdown test

Remove AC power to the

failure. Power

failure.

system for 10 seconds and

cycle AC.

 

restart the system.

 

 

If the problem persists,

 

 

see "Getting Help" on

 

 

page 187.

36

About Your System

Page 36
Image 36
Dell R515 owner manual Programmable interval Remove AC power to