Code

Text

Causes

Corrective Actions

 

 

 

 

E2012

Memory

Memory configured,

See "Troubleshooting

 

configured but

but is unusable.

System Memory" on

 

unusable.

 

page 165.

 

Check DIMMs.

 

 

E2013

BIOS unable to

The system BIOS failed

See "Troubleshooting

 

shadow memory.

to copy its flash image

System Memory" on

 

Check DIMMs.

into memory.

page 165.

E2014

CMOS RAM

CMOS failure. CMOS

Remove AC power to the

 

failure. Power

RAM not functioning

system for 10 seconds and

 

cycle AC.

properly.

restart the system.

 

 

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E2015

DMA Controller

DMA controller failure.

Remove AC power to the

 

failure. Power

 

system for 10 seconds and

 

cycle AC.

 

restart the system.

If the problem persists, see "Getting Help" on page 187.

E2016 Interrupt

Interrupt controller

Controller

failure.

failure. Power

 

cycle AC.

 

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Getting Help" on page 187.

E2017 Timer refresh Timer refresh failure.

Remove AC power to the

failure. Power

system for 10 seconds and

cycle AC.

restart the system.

 

If the problem persists,

 

see "Getting Help" on

 

page 187.

About Your System

35

Page 35
Image 35
Dell R515 owner manual Memory configured See Troubleshooting