Message | Causes | Corrective Actions | |
|
|
| |
Unsupported | Invalid memory | Ensure that the memory | |
memory | configuration. | modules are installed in a | |
configuration. | Memory modules are | valid configuration. | |
DIMM mismatch | mismatched in the | See "General Memory | |
specified slots. | Module | ||
across slots | |||
| Installation Guidelines" on | ||
detected: |
| page 105. | |
x,x,... |
|
| |
Unused memory | The memory configuration is | Reconfigure the memory for | |
detected. DIMM’s | not optimal for Advanced | Advanced ECC Memory | |
installed in the | ECC Memory Mode. | Mode, or change the | |
following slot | Modules in the specified | memory mode to Optimized | |
are not available | slots are unused. | or Sparing in the BIOS setup | |
when in |
| screen. See "System | |
advanced ECC |
| Memory" on page 104. | |
mode: x,x,x |
|
| |
Warning: A fatal | A fatal system error | Check the SEL for | |
error has caused | occurred and caused the | information that was logged | |
system reset! | system to reboot. | during the error. See the | |
Please check the |
| applicable troubleshooting | |
system event log! |
| section in "Troubleshooting | |
|
| Your System" on page 157 for | |
|
| any faulty components | |
|
| specified in the SEL. | |
|
|
| |
Warning: Control | The control panel is not | Install the control panel, or | |
Panel is not | installed or has a faulty cable | check the cable connections | |
installed. | connection. | between the display module, | |
|
| the control panel board, | |
|
| and the system board. | |
|
| See "Integrated Storage | |
|
| Controller Card" on | |
|
| page 119. |
52
About Your System