Code | Text | Causes | Corrective Actions |
|
|
|
|
E122A | CPU # VTT | Specified processor | Reseat the processor(s). |
| Regulator | VTT voltage regulator | See "Troubleshooting |
| failure. | has failed. | Processors" on page 174. |
| Reseat CPU. |
| If the problem persists, |
|
|
| see "Getting Help" on |
|
|
| page 187. |
E122C CPU Power | A power fault was |
Fault. Power | detected when powering |
cycle AC. | up the processor(s). |
Remove AC power to the system for 10 seconds and restart the system.
If the problem persists, see "Getting Help" on page 187.
E122D | Memory | One of the memory | Reseat the memory |
| Regulator # | regulators has failed. | modules. See |
| Failed. |
| "Troubleshooting System |
| Reseat DIMMs. |
| Memory" on page 165. |
E122E | One of the | Remove AC power to the | |
| regulator | voltage regulators has | system for 10 seconds and |
| failed. | failed. | restart the system. |
| Call support. |
| If the problem persists, |
|
|
| see "Getting Help" on |
|
|
| page 187. |
|
|
|
|
E1310 | Fan ## RPM | RPM of specified fan is | See "Troubleshooting |
| exceeding | outside of the intended | System Cooling |
| range. | operating range. | Problems" on page 163. |
| Check fan. |
|
|
E1313 | Fan redundancy | The system is no longer | Check LCD for |
| lost. | fan redundant. Another | additional scrolling |
| Check fans. | fan failure would put the | messages. See |
|
| system at risk of | "Troubleshooting a Fan" |
|
| overheating. | on page 164. |
About Your System
29