Any of these actions will remove fault messages, and return the status indicators and LCD colors to the normal state. Messages will reappear under the following conditions:
•The sensor returns to a normal state but fails again, resulting in a new SEL entry.
•The system is reset and new error events are detected.
•A failure is recorded from another source that maps to the same display entry.
System Messages
System messages appear on the screen to notify you of a possible problem with the system.
NOTE: If you receive a system message not listed in the table, check the documentation for the application that is running or the operating system's documentation for an explanation of the message and recommended action.
Message | Causes | Corrective Actions |
|
|
|
Alert! iDRAC6 not | The optional iDRAC6 is not | Wait for the system |
responding. | responding to BIOS | to reboot. |
Rebooting. | communication either |
|
| because it is not functioning |
|
| properly or has not |
|
| completed initialization. |
|
| The system reboots. |
|
Alert! iDRAC6 not responding. Power required may exceed PSU wattage.
Alert! Continuing system boot accepts the risk that system may power down without warning.
The optional iDRAC6 has hung.
The optional iDRAC6 was remotely reset while system was booting.
After AC recovery, the optional iDRAC6 takes longer than normal to boot.
Remove AC power to the system for 10 seconds and restart the system.
40
About Your System