Message

Causes

Corrective Actions

 

 

 

Alert! Node

The memory configuration

Ensure that the memory

Interleaving

does not support node

modules are installed in a

disabled! Memory

interleaving, or the

configuration that supports

configuration

configuration has changed

node interleaving.

does not support

(for example, a memory

Check other system

Node

module has failed) so that

messages for additional

Interleaving.

node interleaving cannot be

information for possible

 

supported. The system still

causes. For memory

 

runs, but without node

configuration information,

 

interleaving.

see "General Memory

 

 

Module

 

 

Installation Guidelines" on

 

 

page 105. If the problem

 

 

persists,

 

 

see "Troubleshooting System

 

 

Memory" on page 165.

 

 

 

Alert! Power

The system configuration

If any system components

required exceeds

of processor(s),

were just upgraded,

PSU wattage.

memory modules,

return the system to the

Check PSU and

and expansion cards may

previous configuration.

system

not be supported by the

If the system boots without

configuration.

power supplies.

this warning, then the

Alert!

 

replaced component(s) are

 

not supported with this

Continuing

 

 

power supply. If Energy

system boot

 

 

Smart power supplies are

accepts the risk

 

 

installed, replace them with

that system may

 

 

High Output power supplies

power down

 

 

to use the components.

without warning.

 

 

See "Power Supplies" on

 

 

 

 

page 102.

 

 

 

Alert! System

An error caused the

Check other system

fatal error

system to reboot.

messages for additional

during previous

 

information for possible

boot.

 

causes.

About Your System

41

Page 41
Image 41
Dell R515 owner manual Memory configuration Ensure that the memory