Code

Text

Causes

Corrective Actions

E2112 Memory spared

The system BIOS has

on DIMM ##.

spared the memory

Power cycle

because it has determined

AC.

the memory had too many

 

errors. "##" represents the

 

memory module

 

implicated by the BIOS.

Remove AC power to the system for 10 seconds and restart the system.

If the problem persists, see "Troubleshooting System Memory" on page 165.

I1910 Intrusion

System cover has been

Information only.

detected.

removed.

 

Check chassis

 

 

cover.

 

 

I1912 System Event

The SEL is full of events

Log full.

and is unable to log any

Review &

more.

clear log.

 

Check the SEL for details on the events, then clear the SEL.

I1920 iDRAC6 Upgrade

Optional iDRAC6 has

Information only.

Successful

been upgraded

 

 

successfully.

 

W1228 RAID

Warns predictively that

Controller

the RAID battery has

battery

less than 24 hours of

capacity <

charge left.

24hr.

 

Allow RAID battery to charge to greater than 24 hours of sustained charge.

If problem persists, replace RAID battery. See "Installing the RAID Battery" on page 137.

W1627 Power required The system configuration

>PSU wattage. requires more power

Check PSU and

than what the power

config.

supply can provide.

Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system.