Code

Text

Causes

Corrective Actions

E1920 iDRAC6 Upgrade

The iDRAC6 Express

Failed

Card is not installed

 

properly or the card is bad.

Reseat the iDRAC6 Express Card. If the problem persists, see "Getting Help" on page 187.

E1A14 SAS cable A

SAS cable A is missing

failure.

or bad.

Check

 

connection.

 

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 187.

E1A15 SAS cable B

SAS cable B is missing

failure.

or bad.

Check

 

connection.

 

Reseat the cable. If the problem persists, replace cable.

If the problem persists, see "Getting Help" on page 187.

E1A1D

Control panel

USB cable to the control

Reseat the cable.

 

USB cable not

panel is missing or bad.

If the problem persists,

 

detected.

 

replace cable.

 

Check cable.

 

If the problem persists,

 

 

 

see "Getting Help" on

 

 

 

page 187.

 

 

 

 

E2010

Memory not

No memory was detected

Install memory or reseat

 

detected.

in the system.

memory modules.

 

Inspect DIMMs.

 

See "Installing Memory

 

 

 

Modules" on page 108 or

 

 

 

"Troubleshooting System

 

 

 

Memory" on page 165.

 

 

 

 

E2011

Memory

Memory detected,

See "Troubleshooting

 

configuration

but is not configurable.

System Memory" on

 

failure.

Error detected during

page 165.

 

Check DIMMs.

memory configuration.

 

34

About Your System

Page 34
Image 34