Environmental specifications

NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.

Temperature

 

Storage

–40°C to 65°C (–40°F to 149°F)

Continuous operation (for altitude less than 950

10°C to 35°C (50°F to 95°F) with no direct

m or 3117 ft)

sunlight on the equipment.

Fresh air

For information on fresh air, see Expanded

 

Operating Temperature section.

Maximum temperature gradient (operating and

20°C/h (36°F/h)

storage)

 

Relative humidity

 

Storage

5% to 95% RH with 33°C (91°F) maximum dew

 

point. Atmosphere must be non-condensing at all

 

times.

Operating

10% to 80% Relative Humidity with 29°C (84.2°F)

 

maximum dew point.

Maximum vibration

 

Operating

0.26 Grms at 5 Hz to 350 Hz (all operation

 

orientations).

Storage

1.88 Grms at 10 Hz to 500 Hz for 15 min (all six

 

sides tested).

Maximum shock

 

Operating

Six consecutively executed shock pulses in the

 

positive and negative x, y, and z axes of 40 G for

 

up to 2.3 ms.

Storage

Maximum altitude

Operating

Storage

Operating temperature de-rating

Up to 35 °C (95 °F)

35 °C to 40 °C (95 °F to 104 °F)

Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms.

3048 m (10,000 ft).

12,000 m (39,370 ft).

Maximum temperature is reduced by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft).

Maximum temperature is reduced by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft).

177

Page 177
Image 177
Dell T630 owner manual