Figure 18. Installing the memory module

1. memory module

2. alignment key

3.memory-module socket ejector (2)

Next steps

1.Install the cooling shroud.

2.Follow the procedure listed in After working inside your system.

3.Press <F2> to enter System Setup, and check the System Memory setting. The system should have changed the value to reflect the installed memory.

4.If the value is incorrect, one or more of the memory modules may not be installed properly. Ensure that the memory modules are firmly seated in the sockets.

5.Run the system memory test in the system diagnostics.

Flex bays

Your system's flex bay supports sixteen 2.5 inch hard drives or four Dell PowerEdge Express Flash devices.

Removing a flex bay

Prerequisites

1.Ensure that you read the Safety instructions.

2.Keep the #2 Phillips screwdriver ready.

3.Follow the procedure listed in Before working inside your system.

68

Page 68
Image 68
Dell T630 owner manual Flex bays, Removing a flex bay