Dell T630 owner manual Assembling and connecting the safety ground wire

Models: T630

1 181
Download 181 pages 27.59 Kb
Page 108
Image 108

Assembling and connecting the safety ground wire

Prerequisites

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

Steps

1.Strip the insulation from the end of the green/yellow wire, exposing approximately 4.5 mm (0.175 inch) of copper wire.

2.Using a hand-crimping tool (Tyco Electronics, 58433-3 or equivalent), crimp the ring-tongue terminal (Jeeson Terminals Inc., R5-4SA or equivalent) to the green/yellow wire (safety ground wire).

3.Connect the safety ground wire to the grounding post on the back of the system using a #6-32 nut equipped with a locking washer.

Figure 39. Assembling and connecting the safety ground wire

1.

#6-32 nut

2.

spring washer

3.

locking washer

4.

safety ground wire

5.grounding post

Assembling the DC input power wires

Prerequisites

WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the product.

108