Part Tests

The Part Tests section is used to define limits for the weld proocess and welder behavior for cases where the process is outside the limits.

The Process Limits button is used to enter limits for weld process results as shown in Figures 5-25, 5-26, and 5-27. The following limits are available:

1.Weld Time (s)

2.Weld Rotations

3.Orientation (Deg.)

4.Weld Energy (J)

5.Peak RPM

6.Peak Torque (% of max.)

7.Peak Thrust (% of max.)

8.Cycle Time (s)

9.Vertical Weld End (mm)

10.Hold Collapse (mm)

11.Hold End Position (mm)

To enable a limit, press the ON/OFF box to the left of the description and enter the Lower and Upper values. Any combination of limits can be enabled simultaneously. The More Limits… button shows additional limits, and the DONE button causes the screen to return to the POST-WELDmain menu.

Figure 5–25Process Limit Definitions Screen 1 of 3

Figure 5–26Process Limit Definitions Screen 2 of 3

 

Figure 5–27Process Limit Definitions Screen 3 of 3

 

 

 