Section 5 - Touch Screen Menus

Parameter Value Range

The minimum and maximum values of the welding parameters are listed in Table 5-I.

Screen

Parameter Name

Min.Value

Max.Value

Resolution

Units

 

 

 

 

 

 

 

TOOL Inertia

 

3000 (SVT012VR)

 

 

 

 

0

780 (SVT032VR)

1

kg* cm²

 

 

 

160 (SVT042VR)

 

 

 

 

 

 

 

 

 

TOOL Weight

0

25..0

0..1

kg

 

 

 

 

 

 

SETUP>

SPIN Decel..

25

200

1

%

 

 

 

 

 

TOP OF STROKE Position

0

140..00

0..01

mm

PRE-WELD

 

 

 

 

 

TRIGGER Position

1..00

140..00

0..01

mm

 

 

 

 

 

 

 

 

Part Pickup Position

1..00

140..00

0..01

mm

 

 

 

 

 

 

 

Part Pickup Thrust

1

100

1

%

 

Part Pickup Timeout

1

60

1

sec..

 

 

 

 

 

 

 

Pre-Spin Orientation

0

359..9

0..1

deg..

 

 

 

 

 

 

 

Weld Time/

 

 

 

sec../

 

Weld Rotations/

 

 

 

rev../

 

Weld Distance (Vertical) /

0..01

50000

0..01

mm/

 

Energy

 

 

 

Joules

 

 

 

 

 

 

 

VERT.. Speed

..01

100..00

0..01

mm/s

 

 

 

 

 

 

SETUP>

SPIN RPM

 

750 (SVT012VR)

 

 

WELD

 

5

3000 (SVT032VR)

1

RPM

 

 

 

4000 (SVT042VR)

 

 

 

Weld Orientation

0

359..9

0..1

deg..

 

 

 

 

 

 

 

Trigger Torque

1

100

1

%

 

 

 

 

 

 

 

Torque Trigger Timeout

1

60

1

sec..

 

 

 

 

 

 

 

Constant Torque

1

100

1

%

 

 

 

 

 

 

 

Constant Torque Timeout

1

60

1

sec..

 

Hold Speed

..01

100

0..01

mm/s

 

 

 

 

 

 

SETUP>

Hold Move Time/

0

140..00

0..01

sec../

Hold Collapse

mm

POST-WELD

 

 

 

 

 

 

 

 

Hold Dwell Time

0

100..00

0..01

sec..

 

 

 

 

 

 

 

 

Hold Constant Thrust

1

100

1

%

 

 

 

 

 

 

TOOLS>

 

 

 

 

 

SYSTEM

Home Offset

0

359..9

0..1

deg

SETUP

 

 

 

 

 

 

 

 

 

 

 

Table 5–IWelding Parameters

Dukane Manual Part No. 403-570-01