Dual Servo Spin Welder User’s Manual
Part Data
Upon startup, the screen will appear as shown in Figure
PART DATA List
This area contains a series of lines of part data, one line per part. This data is displayed after each cycle if the Data Export option in the System Setup screen on the welder is enabled (See Figure
1.Part number (ID)
2.Test result number
3.Test result symbol
4.Date
5.Time
6.Weld time (sec.)
7.Number of weld revolutions
8.Weld energy (Joules)
9.Peak spin motor RPM
10.Peak spin motor torque (% of max.)
11.Weld orientation (degrees)
12.Peak vertical thrust (% of max.)
13.Cycle time (sec.)
14.Weld end distance (mm)
15.Hold relative (collapse) distance (mm)
16. Hold end distance (mm)
CLEAR
Clears parts data from PC screen.
WRITE TO FILE
Writes parts data from the screen to a file on the computer. After pressing this button, enter the name of the file where to store the data. Add a .txt or .csv extension to the end of the file name as the gener- ated file is in ASCII format. Saving the file with a
.csv extension will allow it to be opened directly with Microsoft Excel™.
Figure 8–1 Utility Startup Screen