Troubleshooting
The IS LED of the
The higher the blinking frequency, the more serious the alarm.
The IS LED can be green or red. The working state of the
LED.
The blinking frequency of the IS LED indicates the alarm level:
zFor a minor alarm, the IS LED blinks at a frequency of 0.5 Hz.
zFor a major alarm, the IS LED blinks at a frequency of 1 Hz.
zFor a critical alarm, the IS LED blinks at a frequency of 4 Hz.
Solution
By using the SMM command, query the status and logs of the blade where the alarm occurs.
If an alarm occurs due to over high temperature, confirm that:
1.The temperature in the equipment room meets the operating requirements for the product.
2.The air intake vents and exhaust vents of the shelf are not blocked.
3.Blank filler blades are installed in the vacant slots of the shelf.
4.The fans are adjusted to the required speed.
A.7 Power-On Startup Exceptions
Description
After you close the upper and lower ejector handles of the
Solution
To solve the problem, proceed as follows:
1.Check that the
2.Check that the pointers of the