Installation of the RTM-ATCA-7150
ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B) 39
zHold the ejector handles and the face plate when you insert or remove RTM-ATCA-7150.
Do not touch the components inside of the blades.
zKeep the blade vertical when you install RTM-ATCA-7150. Align the blade with the slot and
then insert it in the shelf.
2.4.1 Ejector Handles
RTM-ATCA-7150 is powered by the server blade in the slot paired with the RTM-ATCA-7150
slot. RTM-ATCA-7150 does not support hot swap. The face plate of ATCA-7150 and RTM-ATCA-
7150 provides an upper and a lower ejector handles. The ejector handles help to insert,
remove, fasten, power on, and power off RTM-ATCA-7150.
2.4.2 ESD Prevention
Static electricity may hurt you or damage the device. To minimize the damage, pay attention
to the following points:
zBefore you operate the device, wear the ESD-preventive wrist strap. Both terminals of the
ESD-preventive wrist strap must contact well. One terminal touches your bare skin, and
the other is inserted in the jack at the front or back side of the shelf. For details on how to
wear the ESD-preventive wrist strap, refer Wearing the ESD-Preventive Wrist Strap.
zAvoid moving your body as much as possible. Movement gathers static electricity around
you.
zDo not touch the solder point, pin, or bare circuit.
zDo not leave the device in the place where others can operate it.
zInstall the device at once after yo u take it out of the antist atic package. If you need to lay
down the device, place it back in the antistatic package. Do not lay the device on the shelf
or cabinet.
zMonitor the temperature and humidity of the equipment room. Warm air decreases the
humidity and increases the static electricity in the room.