Installation of the RTM-ATCA-7150

3.Remove the desiccant bag shipped together with the blade and dispose of it according to your country’s legislation.

The product is thoroughly inspected before shipment. If any damage occurred during transportation or any items are missing, please contact our customer's service immediately.

2.3Environmental and Power Requirements

The following environmental and power requirements are applicable to the board.

2.3.1Environmental Requirements

Table 2-1 Environmental Requirements RTM-ATCA-7150

Requirement

Operating

Non-Operating

 

 

 

Temperature

+5ºC (41ºF) to +40ºC (104ºF) (normal operation)

-40ºC (-40ºF) to +70ºC

 

according to NEBS Standard GR-63-CORE

(158ºF) (may be further

 

-5ºC to +55ºC (short term operation) according

limited by installed

 

accessories)

 

to NEBS Standard GR-63-CORE

 

 

 

 

 

Temp. Change

+/- 0.25ºC/min or 15ºC/h (59ºF/h) according to

+/- 0.25ºC/min or 15ºC/h

 

NEBS Standard GR-63-CORE

(59ºF/h)

 

 

 

Rel. Humidity

5% to 85% non-condensing according to

5% to 85% non-condensing

 

Emerson Network Power Embedded

according to Emerson

 

Computing-internal environmental

Network Power Embedded

 

requirements

Computing-internal

 

 

environmental

 

 

requirements

 

 

 

Altitude

<= 4000m

 

 

 

 

36

ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)

Page 36
Image 36
Emerson manual Environmental and Power Requirements, Environmental Requirements, Installation of the RTM-ATCA-7150