Hardware Installation of ATCA-7150

3.3Environmental and Power Requirements

The following environmental and power rewuirements are applicable to the blade.

3.3.1Environmental Requirements

Table 3-2 Environmental Requirements

 

Requirement

Operating

Non-Operating

 

 

 

 

 

 

 

Temperature

+5ºC (41ºF) to +40ºC (105ºF) (normal

The SAS drives can meet this

 

 

 

operation) according to NEBS Standard GR-

max temperature range of

 

 

 

63-CORE

non-operating.

 

 

 

-5ºC to +55ºC (exceptional operation)

-40ºC (-40ºF) to +70ºC

 

 

 

according to NEBS Standard GR-63-CORE

(158ºF).

 

 

 

 

 

 

 

Temp. Change

+/- 0.25ºC/min according to NEBS Standard

+/- 0.25ºC/min

 

 

 

GR-63-CORE

 

 

 

 

 

 

 

 

Rel. Humidity

5% to 85% non-condensing according to

5% to 95% non-condensing

 

 

 

Emerson Network Power-internal

according to Emerson

 

 

 

environmental requirements

Network Power-internal

 

 

 

 

environmental

 

 

 

 

requirements

 

 

 

 

 

 

 

Altitude

<=3000 m

 

 

 

 

 

 

 

 

Maximum weight

4.0 kg

 

 

 

 

 

 

 

 

Length x width x

322.3 mm × 280 mm × 29 mm

 

 

 

height

 

 

 

 

 

 

 

 

 

Vibration

0.1g from 5 to 100 Hz and back to 5 Hz at a

5-20 Hz at 0.01 g2/Hz

 

 

 

rate of 0.1 octave/minute

20-200 Hz at -3.0 dB/octave

 

 

 

 

 

 

 

 

Random 5-20 Hz at 1

 

 

 

 

m2/Sec3

 

 

 

 

Random 20-200 Hz at -3

 

 

 

 

m/Sec2

 

 

Shock

Half-sine, 11 m/Sec, 30mSec/sec2

Blade level packaging

 

 

 

 

Half-sine, 6 mSec at 180

 

 

 

 

m/Sec2

 

 

 

 

 

 

ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)

71

Page 71
Image 71
Emerson RTM-ATCA-7150 manual Environmental and Power Requirements, Environmental Requirements