Table 3-2 Environmental Requirements (continued)

Requirement

Operating

Non-Operating

 

 

 

Free Fall

 

1,200 mm (Packaged) /all

 

 

edges and corners

 

 

1.0m (Packaged) per ETSI

 

 

300 019-2-2 (Blade level

 

 

packaging)

 

 

25 mm (unpackaged) per

 

 

GR-63-CORE

 

 

 

3.3.2Power Requirements

Make sure that the blade is used in an AdvancedTCA shelf connected to -48VDC up to -60VDC, according to Telecommunication Network Voltage (TNV-2). A TNV-2 circuit is a circuit whose normal operating voltages exceed the limits for a safety-extra-low-voltage (SELV) under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.

Table 3-3lists the power requirements for the ATCA-7150.

Table 3-3 Power Requirements

Requirement

Operating

 

 

Rated Voltage

-48VDC to -60VDC

 

US and Canada: -48VDC

 

 

Operating Voltage

-39.0VDC to -72VDC

 

US and Canada: -39.0 to -60VDC

 

 

Input Current

3.75A at 48V

 

 

Power Dissipation

180W (max) 140W (min)

 

 

The blade provides two independent power inputs according to the AdvancedTCA specification.