Hardware Installation of ATCA-7150

3.6.5.2Replacing the Hard Disk

To replace the hard disk, proceed as follows:

1.Wear the ESD-preventive wrist strap.

For details, see Wearing the ESD-Preventive Wrist Strap on page 75.

2.Remove the ATCA-7150 whose hard disk is to be replaced. For details, see Removing the ATCA-7150on page 95.

3.Remove the finger on the hard disk holder in a direction as shown in Figure 3-7to unlock the hard disk.

4.Exert even force to pull the hard disk holder from the fixing bracket, as shown in Figure 3-7.

5.Unfasten the four screws used to fasten the hard disk anticlockwise, as shown in Figure 3-7.

6.Exert even force to pull the hard disk from the holder, as shown in Figure 3-7.

7.Place the faulty hard disk in the antistatic package.

8.Take the new hard disk out of the antistatic package.

9.Install the new hard disk.

For details, see Installing the Hard Disk on page 86.

10.Install the ATCA-7150 with the hard disk replaced.

For details, see Installing the ATCA-7150 in a Powered Shelf on page 91.

ATCA-7150 and RTM-ATCA-7150 Getting Started (6806800G42B)

89

Page 89
Image 89
Emerson RTM-ATCA-7150 manual Hardware Installation of ATCA-7150 Replacing the Hard Disk