Default Values and Ranges

Table A-1Transmitter default values and ranges continued

Type

Setting

Default

Range

Comments

 

 

 

 

 

Density

Density damping

1.6 sec

0.0–51.2 sec

User-entered value is

 

 

 

 

corrected to nearest lower

 

 

 

 

value in list of preset values.

 

 

 

 

 

 

Density units

g/cm3

 

 

 

 

 

 

 

 

Density cutoff

0.2 g/cm3

0.0–0.5 g/cm3

 

 

 

 

 

 

 

D1

0.00000

 

 

 

 

 

 

 

 

D2

1.00000

 

 

 

 

 

 

 

 

K1

1000.00

 

 

 

 

 

 

 

 

K2

50,000.00

 

 

 

 

 

 

 

 

FD

0.00000

 

 

 

 

 

 

 

 

Temp Coefficient

4.44

 

 

 

 

 

 

 

Slug flow

Slug flow low limit

0.0 g/cm3

0.0–10.0 g/cm3

 

 

 

 

 

 

 

Slug flow high limit

5.0 g/cm3

0.0–10.0 g/cm3

 

 

 

 

 

 

 

Slug duration

0.0 sec

0.0–60.0 sec

 

 

 

 

 

 

Temperature

Temperature damping

4.8 sec

0.0–38.4 sec

User-entered value is

 

 

 

 

corrected to nearest lower

 

 

 

 

value in list of preset values.

 

 

 

 

 

 

Temperature units

Deg C

 

 

 

 

 

 

 

 

Temperature calibration factor

1.00000T0.0000

 

 

 

 

 

 

 

Pressure

Pressure units

PSI

 

 

 

 

 

 

 

 

Flow factor

0.00000

 

 

 

 

 

 

 

 

Density factor

0.00000

 

 

 

 

 

 

 

 

Cal pressure

0.00000

 

 

 

 

 

 

 

T-Series sensor

D3

0.00000

 

 

 

 

 

 

 

 

D4

0.00000

 

 

 

 

 

 

 

 

K3

0.00000

 

 

 

 

 

 

 

 

K4

0.00000

 

 

 

 

 

 

 

 

FTG

0.00000

 

 

 

 

 

 

 

 

FFQ

0.00000

 

 

 

 

 

 

 

 

DTG

0.00000

 

 

 

 

 

 

 

 

DFQ1

0.00000

 

 

 

 

 

 

 

 

DFQ2

0.00000

 

 

 

 

 

 

 

Special units

Base mass unit

g

 

 

 

 

 

 

 

 

Base mass time

sec

 

 

 

 

 

 

 

 

Mass flow conversion factor

1.00000

 

 

 

 

 

 

 

 

Base volume unit

L

 

 

 

 

 

 

 

 

Base volume time

sec

 

 

 

 

 

 

 

 

Volume flow conversion factor

1.00000

 

 

 

 

 

 

 

Event 1

Variable

Density

 

 

 

 

 

 

 

 

Type

Low alarm

 

 

 

 

 

 

 

 

Setpoint

0.0

 

 

 

 

 

 

 

 

Setpoint units

g/cm3

 

 

 

 

 

 

 

116

Micro Motion® Model 1500 Transmitters with the Filling and Dosing Application