Figure 8-2Discrete IO panel

Using the Filling and Dosing Application

Figure 8-2Discrete IO panel

Table 8-3Fill control functions

Function

ON state actions

 

 

Begin fill

• Starts the fill.

 

• The fill total is automatically reset before filling begins.

 

 

End fill

• Permanently stops the fill.

 

• The fill cannot be resumed.

 

 

Pause fill

• Temporarily stops the fill.

 

• The fill can be resumed if the fill total is less than the fill target.

 

 

Resume fill

• Restarts a fill that has been paused.

 

• Counting resumes from the point at which the fill was paused.

 

 

Reset fill total

• Resets fill total to zero.

Reset cannot be performed while a fill is running or while a fill is paused. Before a fill can be reset, the fill target must be reached or the fill must be ended.

Note: The Reset All Totals function (see Section 4.7) includes resetting the fill total.