Required Transmitter Configuration

View the trend chart for these initial tests. By default, the specification uncertainty limit is set at ±4.0%, which will avoid false Fail/Caution results over the entire range of specified process conditions. If you observe a structural integrity variation greater than 4% due to normal process conditions, you may adjust the specification uncertainty limit to match your process variation. To avoid false Fail/Caution results, it is advisable to set the specification uncertainty limit to approximately twice the variation due to the effect of normal process conditions.

In order to perform this baseline analysis, you will need the enhanced meter verification capabilities of ProLink II v2.5 or later. Refer to the manual entitled ProLink® II Software for Micro Motion® Transmitters: Installation and Use, P/N 20001909, Rev D or later.

30

Micro Motion® Model 1500 Transmitters with the Filling and Dosing Application