Emerson Process Management 1500 manual Menu Flowcharts, Filling

Models: 1500

1 146
Download 146 pages 48.94 Kb
Page 136
Image 136
Filling

Menu Flowcharts

Figure C-4ProLink II configuration menu continued

ProLink Menu

Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filling

Analog output

 

Device

Flow source

Primary variable is

 

· Tag

Filling control options

Process variable measurement

 

· Date

 

· Descriptor

· Enable filling option

· Lower range value

 

· Message

· Count up

· Upper range value

 

· Sensor type

· Enable AOC

· AO cutoff

 

· Transmitter serial

· Enable purge

· AO added damp

 

· Floating pt ordering

· Fill type

· Lower sensor limit

 

· Add comm resp delay

· Configure by

· Upper sensor limit

 

 

 

 

· Fill target

· Min span

 

Digital comm settings

· Max fill time

· AO fault action

 

·

Digital comm fault

· Purge mode

· AO fault level

 

 

setting

· Purge delay

· Last measured value timeout

 

·

Modbus address

· Purge time

Valve control options

 

 

 

 

· AOC algorithm

 

Update rate

· AOC window length

· Enable 3 position valve

 

·

Update rate

· Fixed overshoot comp

· Analog valve setpoint

 

·

100 Hz variable

Discrete valves for 2 stage filling

· Analog valve closed value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

· Open primary

 

 

 

 

 

 

 

 

 

· Open secondary

 

 

 

 

 

 

 

 

 

· Close primary

 

 

 

 

 

 

 

 

 

· Close secondary

 

 

 

 

 

 

 

 

 

3 position analog valve

·Open full

·Close partial

 

 

 

 

 

 

 

 

 

 

 

Channel

 

RS-485

 

 

Alarm

 

Discrete IO

Channel B

 

· Protocol

 

 

· Alarm severity

 

Discrete output

 

 

 

 

· Type assignment

 

· Baud rate

 

 

 

 

· DO1 assignment

 

 

 

 

 

· Power type

 

· Parity

 

 

 

 

· DO1 polarity

 

 

 

· Stop bits

 

 

Variable mapping

 

· DO2 assignment

Channel C

 

 

 

 

 

· Primary variable

 

· DO2 polarity

 

 

 

 

 

 

· Type assignment

 

 

 

 

 

 

 

 

· Power type

 

 

 

 

 

 

 

Discrete input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

· DI assignment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The DO2 options are available only if Channel C has been configured for discrete output.

Note: The discrete input options are available only if Channel C has been configured for discrete input.

128

Micro Motion® Model 1500 Transmitters with the Filling and Dosing Application

Page 136