Default Values and Ranges

Table A-1Transmitter default values and ranges continued

Type

Setting

Default

Range

Comments

 

 

 

 

 

Event 2

Variable

Density

 

 

 

 

 

 

 

 

Type

Low alarm

 

 

 

 

 

 

 

 

Setpoint

0.0

 

 

 

 

 

 

 

 

Setpoint units

g/cm3

 

 

 

 

 

 

 

Update Rate

Update rate

Special

Normal or

 

 

 

 

Special

 

 

 

 

 

 

Analog output

Primary variable

Mass flow

 

 

 

 

 

 

 

 

LRV

–200.00000 g/s

 

 

 

 

 

 

 

 

URV

200.00000 g/s

 

 

 

 

 

 

 

 

AO cutoff

0.00000 g/s

 

 

 

 

 

 

 

 

AO added damping

0.00000 sec

 

 

 

 

 

 

 

 

LSL

–200 g/s

 

Read-only

 

 

 

 

 

 

USL

200 g/s

 

Read-only

 

 

 

 

 

 

MinSpan

0.3 g/s

 

Read-only

 

 

 

 

 

 

Fault action

Downscale

 

 

 

 

 

 

 

 

AO fault level – downscale

2.0 mA

1.0–3.6 mA

 

 

 

 

 

 

 

AO fault level – upscale

22 mA

21.0–24.0 mA

 

 

 

 

 

 

 

Last measured value timeout

0.00 sec

 

 

 

 

 

 

 

LRV

Mass flow

–200.000 g/s

 

 

 

 

 

 

 

 

Volume flow

–0.200 l/s

 

 

 

 

 

 

 

URV

Mass flow

200.000 g/s

 

 

 

 

 

 

 

 

Volume flow

0.200 l/s

 

 

 

 

 

 

 

Fill

Flow source

Mass flow rate

 

 

 

 

 

 

 

 

Enable Filling Option

Enabled

 

 

 

 

 

 

 

 

Count Up

Enabled

 

 

 

 

 

 

 

 

Enable AOC

Enabled

 

 

 

 

 

 

 

 

Enable Purge

Disabled

 

 

 

 

 

 

 

 

Fill Type

One Stage Discrete

 

 

 

 

 

 

 

 

Configure By

% Target

 

 

 

 

 

 

 

 

Fill Target

0.00000 g

 

 

 

 

 

 

 

 

Max Fill Time

0.00000 sec

 

 

 

 

 

 

 

 

Purge Mode

Manual

 

 

 

 

 

 

 

 

Purge Delay

2.00000 sec

 

 

 

 

 

 

 

 

Purge Time

1.00000 sec

 

 

 

 

 

 

 

 

AOC Algorithm

Underfill

 

 

 

 

 

 

 

 

AOC Window Length

10

 

 

 

 

 

 

 

 

Fixed Overshoot Comp

0.00000

 

 

 

 

 

 

 

Valve control –

Open Primary

0.00% of target

0.00–100 %

 

Two-stage

 

 

 

 

Open Secondary

0.00% of target

0.00–100 %

 

discrete fill

 

 

 

 

 

 

Close Primary

100.00% of target

0.00–100 %

 

 

 

 

 

 

 

Close Secondary

100.00% of target

0.00–100 %

 

 

 

 

 

 

Compensation

Measurement Performance

Troubleshooting

Defaults

Configuration and Use Manual

117