Using the Filling and Dosing Application

Table 8-1Run Filler displays and controls continued

Display/Control

Description

 

 

 

Fill Statistics

Fill Total Average

Displays the calculated average of all fill totals since fill statistics were reset.

 

 

 

 

Fill Total Variance

Displays the calculated variance of all fill totals since fill statistics were reset.

 

 

 

 

Reset Fill Statistics

Resets fill total average and fill total variance to zero.

 

 

 

Fill Data

Fill Time

Displays the number of seconds that have elapsed in the current fill. Seconds

 

 

that the fill was paused are not included in the fill time value.

 

 

 

 

Fill Count

Displays the number of fills that have been performed since fill statistics were

 

 

reset. Only completed fills are counted; fills that were ended before the target

 

 

was reached are not included in this total. The maximum number is 65535; after

 

 

that number has been reached, counting resumes with 1.

 

 

 

 

Reset Fill Count

Resets the fill counter to zero.

 

 

 

(1)This field displays the result of AOC calibration. If you reset it manually, AOC calibration data is lost. Typically, the only reason to set it manually is to prevent overfill on the first few fills. See Section 7.5.

(2)Applicable only when AOC Algorithm is set to Underfill.

Table 8-2Fill Status fields

Status LED

Description

 

 

Max Fill Time Exceeded

The current fill has exceeded the current setting for Max Fill Time. The fill is aborted.

 

 

Filling In Progress

A fill is currently being performed.

 

 

Cleaning In Progress

The Start Clean function has been activated, and all valves assigned to transmitter

 

outputs are open (except purge valve)

 

 

Purge In Progress

A purge has been started, either automatically or manually.

 

 

Purge Delay Phase

An automatic purge cycle is in progress, and is currently in the delay period between

 

the completion of the fill and the start of the purge.

 

 

Primary Valve

The primary valve is open. If a three-position analog valve has been configured, the

 

valve is either open or closed partial.

 

 

Secondary Valve

The secondary valve is open.

 

 

Start Not Okay

One or more conditions required to start a fill are not met.

 

 

AOC Flow Rate Too High

The last measured flow rate is too large to allow the fill to start. In other words, the AOC

 

coefficient, compensated for the flow rate, specifies that the valve close command

 

should be issued before the fill has begun. This can happen if the flow rate has

 

increased significantly with no corresponding change in the AOC coefficient. AOC

 

calibration is recommended. To adjust the AOC value, you can use the Override

 

Blocked Start function to run a fill without AOC (see Table 8-1).

 

 

AOC Calibration Active

AOC calibration is in progress.

 

 

8.3.2Using a discrete input

If a discrete input is assigned to a fill control function, the function is triggered when the discrete input is in an ON state.

Table 8-3 lists the fill control functions. To assign a discrete input to trigger a fill function:

1.Ensure that Channel C is configured as a discrete input (see Section 4.3).

2.Open the ProLink II Configuration window and click on the Discrete IO tab. The panel shown in Figure 8-2 is displayed.

3.Select the fill control function to be triggered. Fill control functions are listed and defined in Table 8-3.