RPM4™ OPERATION AND MAINTENANCE MANUAL

PM

Pressure multiplier, used to adjust span of a Q-RPT or barometer to calibrate it.

Parallel Measurement

Operating mode of RPM4s with two Q-RPTs in which both Q-RPTs are used to measure

together in parallel and the indicated pressure is the average of their readings. This

Mode

creates a pseudo Q-RPT designated HL.

 

 

 

 

 

 

Pmax!

The maximum pressure limit of a Q-RPT.

If the pressure measured by the Q-RPT

exceeds Pmax!, an overpressure condition occurs.

 

PPC3

Pressure controller calibrator manufactured by DHI. RPM4 can be used as an external

reference device for a PPC3. PPC3 automates RPM4 pressure control.

 

 

The transducer used by RPM4 for low uncertainty pressure measurement. May be

Q-RPT

designated as Hi, Lo or HL depending on its position and role in t he RPM4.

(Quartz Reference

Q-RPTs are designated by a leading A, G or BG (absolute, gauge or bi-directional

Pressure Transducer)

gauge) followed by three numbers and a letter indicating the maximum range of the

 

Q-RPT in kPa (nnnK) or MPa (nnnM).

 

Rate

A DISPLAY function in which the rate of change of pressure in pressure unit/second is

displayed.

 

 

 

 

Front panel LED indication of when the pressure measured by RPM4’s active Q-RPT is

Ready/Not Ready

stable within the stability limit. Leading character of the second line when the inactive Q-

 

RPT is displayed on the second line in RPT DISPLAY mode.

RPT2x

Parallel measurement mode in which both Q-RPTs of an RPM4 with two Q-RPTs are

used together and the indicated pressure is the average of their measurements.

 

SDS (Self Defense

A system to protect Q-RPTs from overpressure made up of isolation and vent valves

System)

and internal operating logic. Applies only to Q-RPTs designated A7M or lower.

Span

The difference between FS and the lowest point in a range. For example, the span of a

100 kPa FS range in negative gauge mode is nominally 200 kPa (from - 100 kPa to 100 kPa).

 

 

A limit expressed in units of pressure per second (e.g., kPa/second). The stability limit is used

Stability Limit

as the Ready/Not Ready criterion. Ready if rate of change is less than stability limit.

 

Not Ready if rate of change is greater than stability limit.

Target

The value from which deviations are measured in the Deviation DISPLAY function.

UL (Upper Limit)

A user settable maximum pressure limit.

When pressure exceeds UL, RPM4 beeps

intermittently. In negative gauge measurement mode, there is also a user settable lower limit.

 

User Level

Levels of security that can be set to protect certain RPM4 functions from being accessed.

QDUT

On-board automated test sequence that AutoRanges RPM4 based on characteristics of

the Device Under Test (DUT).

 

 

 