Chapter 9 Operational Settings

Item

Explanation

Selectable Parameters

Default

Connection via

Connection via

 

 

 

 

SCSI/USB

SCSI/USB

 

 

 

 

Connector 1

Connector 2

 

 

 

 

 

 

Page Counter

For evaluating the consumable

After cleaning/Brake Roller/Pick Roller

0 pages

Yes

Yes

(Consumables

replacement cycle.

 

 

 

 

Remaining Ink (only when the imprinter

Shown only

 

 

counters)

Use this function to reset the

 

 

option for fi-6670/fi-6670A is installed)

when the

 

 

 

counters after replacing the consum-

 

 

 

 

imprinter

 

 

 

ables.

 

 

 

 

 

option for fi-

 

 

 

 

 

 

 

 

 

 

6670/fi-

 

 

 

 

 

6670A is

 

 

 

 

 

installed.

 

 

 

 

 

 

 

 

Power saving

Specify the waiting time before

Setting range: 15 to 55 min. (in steps of

15 min.

Yes

Yes

 

entering the Power saving mode.

5 min.)

 

 

 

 

 

 

 

 

 

Offset

Adjust the starting position for the

Unit:

Main/Sub:

Yes

Yes

 

document scanning.

For connection via SCSI/USB Connec-

0 mm

 

 

 

 

tor 1:

 

 

 

 

 

ADF (Front), ADF (Back) (fi-6670/fi-

 

 

 

 

 

6670A/fi-6770/fi-6770A only)

 

 

 

 

 

Flat Bed (Flatbed type only)

 

 

 

 

 

For connection via SCSI/USB Connec-

 

 

 

 

 

tor 2:

 

 

 

 

 

ADF (Back), Flat Bed (fi-6770/fi-6770A

 

 

 

 

 

only)

 

 

 

 

 

Main/Sub: -2 mm to 3 mm (in steps of

 

 

 

 

 

0.5 mm)

 

 

 

 

 

 

 

 

 

Vertical magnification

Adjust the magnification in the

Unit: ADF, Flat Bed (Flatbed type only)

0%

Yes

Yes

Adjustment

feeding direction on the scanning

Setting range: -3.1 to 3.1% (in steps of

 

 

 

 

side specified for [Unit].

0.1%)

 

 

 

 

 

 

 

 

 

Yes: Configurable