Chapter 9 Operational Settings

TOP

3 Select [Non-rectangular document], [Document with tab], or [Document without tab].

Item

Description

 

 

Non-rectangular

Scan extra 120 mm from the detected

document

bottom edge of the document.

 

 

Document with tab

Scan extra 20 mm from the detected

 

bottom edge of the document.

 

 

Document without

Terminates scanning at the time the

tab

bottom edge of the document is detected.

 

 

The scanning speed slows down if [Document with

tab] or [Non-rectangular document] is selected.

When scanning a document with tab or a non-rectan- gular document, refer to "Loading Documents with Tabs or Non-Rectangular Documents" (on page 45).

For how to specify "Auto Paper Size Detection," refer to "Automatically Correcting Skewed Document Images" (on page 87).

When the connection is via SCSI/USB Connector 2, note that:

-You cannot select [Non-rectangular document].

-If you scan a document having a tab, which is smaller than A5, the tab image (in part or whole) may be lost.

-you cannot enable this setting together with [Scan Setting for Document in Dark Background Color]. If you enable this setting, the setting for [Scan Setting for Document in Dark Background Color] will auto- matically be disabled.

Scan Setting for The Document Whose One Side Is in Dark Background Color

[Scan Setting for Document in Dark Background Color]

You can specify whether or not to detect the edge of document in a dark background color during scanning.

You can specify a density of background color so the edge will be detected correctly.

If this option is enabled, the settings for scanning documents with tabs will automatically be disabled.

1 Start up the Software Operation Panel.

Refer to "9.1 Starting Up the Software Operation Panel" (on page 156).

2 From the tree listing on the left, select [Device Setting 2]

D[Scan Setting for Document in Dark Background Color]

D[Enable].

Contents

Index

Introduction

Scanner

Overview

Loading Documents

How to Use ScandAll PRO

Scan Parameters

Various

Documents

Daily Care

Consumables

Troubleshooting

Operational Settings

Appendix

Glossary

176