Chapter 9 Operational Settings

Setting Example 2 : Selected range = Enable, Start = 0 mm, End =0 mm

35

directionFeeding

300

 

Unit: mm

A multifeed error will be detected only for the blue-shaded area in the figure above.

When [Check Overlapping(Ultrasonic)] is selected, the multi- feed detection ratio may drop if the document sheet(s) are glued or electrostatically adhered to each other.

Setting Example 3 (Bad Example): Selected range = Enable, Start = 100 mm, End =102 mm

35

 

100

directionFeeding

2

300

 

Unit: mm

Since the detection range (length) is less than the minimum value (5 mm), the Multifeed Detection cannot be performed

correctly.