Chapter 9 Operational Settings
•Once the starting and ending positions are set to "0," the whole range of the document will be checked for multifeeds regardless of whether "Enable" or "Disable" is selected under [Selected range].
•To disable the Multifeed Detection for the entire document, select [Disable] and configure the settings so the starting position will be "0," and the ending position be equal to or not smaller than the "document length."
•If the starting position is set larger than the document length; with [Disable], the whole range covering the entire document length will be checked; with [Enable], the Multifeed Detection will be disabled.
•To detect multifeeds, the detection range should be at least 5 mm in length.Configure the settings so the ending position minus the starting position be 6 mm or more.
•You can also specify the starting and ending positions in either of the following ways:
-Create a square or rectangle to indicate the detection range by dragging your mouse pointer within the displayed image in the dialog box.
-Drag the handle for the detection range to change the starting and ending positions using the mouse pointer within the displayed image in the dialog box.
Setting Example 1: Selected range = Enable, Start = 50 mm, End = 200 mm
35
50
200
Feeding direction
Unit: mm
A multifeed error will be detected only for the
183