Chapter 9 Operational Settings

9.4 Settings Related to Scanning

Adjusting the Starting Position for Scanning

3 Adjust the offset/scan scale as necessary.

[Offset/Vertical Magnification Adjustment]

 

 

 

When the position of the scanned image is not correct or the image looks elongated in a vertical direction, use the following procedure to adjust the offset and the scan scale for correc- tion.

The factory default settings are appropriate, so normally there is no need to make any adjustment.

1 Start up the Software Operation Panel.

Refer to "9.1 Starting Up the Software Operation Panel" (on page 156).

2 From the tree listing on the left, select [Device Setting]

and then click the [Offset] button.

 

 

Offset

Description

 

 

Setting

 

 

 

 

 

Unit

Select [ADF (front)] or [ADF (back)] (fi-6670/fi-

 

 

6670A/fi-6770/fi-6770A only), or [Flat Bed] (flatbed

 

 

type only) as the target of offset adjustment.

 

 

When the connection is via SCSI/USB Connector

 

 

2, the offset for scanning with the ADF is adjustable

 

 

for the back-side pages only.

 

 

 

 

Main

Adjusts the horizontal (widthwise) offset.

 

 

The setting range is from -2 mm to +3 mm in steps

 

 

of 0.5 mm.

 

 

 

 

Sub

Adjusts the vertical (lengthwise) offset.

 

 

The setting range is from -2 mm to +3 mm in steps

 

 

of 0.5 mm.

 

 

 