Appendix A: Server Specifications
Environmental specificationsThe following specifications identify maximum environmental conditions. At no time should the server run under conditions which violate these specifications.
Variable | Requirements |
|
|
Temperature | Maximum rate of change: 18°F (10°C) per hour |
| Nonoperating: |
| Operating: 50° to 95°F (10° to 35°C); derated 0.9°F (0.5°C) for every |
| 1,000 feet (305 meters) |
|
|
Max BTU/hr. | 5100 |
|
|
Altitude | |
|
|
Humidity | Nonoperating: 95% (noncondensing) at 77° to 86° F (25° to 30° C) |
|
|
Vibration | 2.2 Grms, 10 minutes per axis on each of the three axis. |
|
|
Shock | Operating: 2.0 g, 11 msec, ½ sine (100 pulses in each direction, on |
| each of three axes) |
| |
| V: 175 inches/sec on bottom face drop, 90 inches/sec on the other |
| five faces |
|
|
230 | www.gateway.com |